The QUIDEL TRIAGE TOX Drug Screen, 94600 is a fluorescence immunoassay to be used with the QUIDE™L TRIAGE™ METERPRO™ System for the qualitative determination of the presence of drug and/or the major metabolites above the threshold concentrations of up to 9 distinct drug classes, including assays for amphetamines, methamphetamines, barbiturates, benzodiazepines, cocaine, EDDP, opiates, THC and tricyclic antidepressants in human urine.
Please see chart below for ordering information.
The QUIDEL TRIAGE TOX Drug Screen, 94600 is a fluorescence immunoassay to be used with the QUIDE™L TRIAGE™ METERPRO™ System for the qualitative determination of the presence of drug and/or the major metabolites above the threshold concentrations of up to 9 distinct drug classes, including assays for amphetamines, methamphetamines, barbiturates, benzodiazepines, cocaine, EDDP, opiates, THC and tricyclic antidepressants in human urine.
Please see chart below for ordering information.
| Ordering information | ||
| Catalog number | Description | Kit Size / Case size |
| 94600 | QUIDEL TRIAGE TOX Drug Screen, 94600 (9 drug panel) AMP, mAMP, BAR, BZO, COC, EDDP, OPI, THC, TCA | 25 tests |
| 94613 | QUIDEL TRIAGE TOX Drug Screen, 94600 Control 1 | 5 x 0.25 mL |
| 94614 | QUIDEL TRIAGE TOX Drug Screen, 94600 Control 2 | 5 x 0.25 mL |
Supplemental visual read tests provide flexibility for menu expansion.
| ||
| DOA-A144C | Alltest CLIA Waived Rapid Visual Read Test Panel: BUP, MDMA, OXY, PCP | 25 tests |
| DFY-A102C | Alltest CLIA waived Rapid Fentanyl | 25 tests |
External controls available through Biochemical Diagnostics, Inc., Kovaintl.com | ||
| For use with Alltest CLIA Waived Multi-drug rapid panel: 702001 Statskreen Control kit 17, POS NEG 2 x 5.0 mL | ||
| For use with Alltest CLIA Waived Fentanyl Cassette: 702038 Fentanyl, POS NEG Controls, 2 x 5.0 mL | ||
Evaluation panel | ||
| 26797 | Biochemical Diagnostics Evaluation Panel - Used for method validation with QUIDEL™ TRIAGE™ TOX Drug Screen, 94600 and Rapid Visual Read tests. | 20 x 3.0 mL |
Features & benefits
Built-in QC satisfies daily QC, External POS/NEG QC run once per month.
Patient sample is automatically analyzed against the lot-specific, multi-point calibration curve provided via the CODE CHIP™ module.
Qualitative POS/NEG results are displayed, printed and can be transmitted.
To access safety data sheets, package inserts, quick reference guides and all other technical and promotional materials, visit our technical documents library.